Moberg Pick-Up Test (MPUT)
- Fysiobasen
- Dec 18, 2025
- 3 min read
Updated: Jan 20
The Moberg Pick-Up Test (MPUT) is a standardized assessment tool designed to evaluate hand function, focusing on manual dexterity and functional sensibility. It is intended to be quick, simple, reproducible, and cost-effective in clinical practice¹

Target Population
The MPUT is useful for patients with hand-related conditions, including:
Carpal tunnel syndrome²
Inflammatory hand diseases
Rheumatoid arthritis³ā“
Osteoarthritis³
Peripheral nerve injuries
It is applied in both neurological rehabilitationĀ and as a tool to evaluate the effect of treatmentĀ or disease progression.
Method of Administration
Required Equipment
60 Ć 30 cm plastic board
3 Ć 8 Ć 5 cm plastic box
12 small metal objects:
Fine screw (5 cm)
Wide screw (2.3 cm)
Paper clips (3.3 cm and 2.8 cm)
Ring (1.4 cm)
Safety pin (3.8 cm)
Two small nuts
One wing nut
Coins (2.8 cm and 2.2 cm)
Key (5.5 cm)
Stopwatch
Test Procedure
The test is carried out in two phases: first with eyes open, then with eyes closed. The dominant hand is always tested first.
The patient sits on a chair with the plastic board placed on the table.
The box is positioned on the board.
The 12 objects are randomly spread out near the dominant hand.
The patient is instructed to pick up each object one by one and place it in the box as quickly as possible without slidingĀ the objects across the board.
Timing begins at āstartā and ends when the last object is placed in the box.
Ambidextrous patients test the hand they spontaneously prefer first.
The test may also be performed in standing position if needed.
Scoring System
The outcome is measured as time (seconds)Ā from start until the last object is placed in the box.
Higher times = reduced dexterity and function.
Can be performed with both eyes open and eyes closed.
Normative Values (seconds)ā¶
Group | Eyes Open (Dominant) | Eyes Closed (Dominant) |
Women 20ā39 yrs | 12.0 | 23.8 |
Men 20ā39 yrs | 12.3 | 22.5 |
Women 40ā59 yrs | 12.6 | 23.0 |
Men 40ā59 yrs | 16.5 | 27.8 |
Women 60+ yrs | 16.0 | 27.8 |
Men 60+ yrs | 16.8 | 29.9 |
Evidence
Reliability
Testāretest reliability: α = 0.985²ā·
Inter-rater reliability: Good to excellentĀ in patients with carpal tunnel syndrome and rheumatologic conditions³ā“.
Validity
Clinically validated for rheumatic diseases, carpal tunnel syndrome, and osteoarthritis³ā“ā·.
Well-suited to evaluate the effect of surgery, rehabilitation, or occupational therapy interventions.
Clinical Relevance
The MPUT is a simple, cost-effective, and sensitive toolĀ providing objective information about hand function. It is highly useful for:
Tracking patient progress in hand-related conditions
Supporting treatment planning
Documenting the effect of surgical or therapeutic interventions
It also serves as a valuable supplementĀ to other functional hand tests and patient-reported outcome measures.
Sources:
Santos-Eggimann B, Ballan K, Fustinoni S, Büla C. Measuring Slowness in Old Age: Times to Perform Moberg Picking-Up and Walking Speed Tests. Journal of the American Medical Directors Association. 2020 May 11
Amirjani N, Ashworth NL, Olson JL, Morhart M, Ming Chan K. Discriminative validity and testāretest reliability of the Dellonāmodified Moberg pickāup test in carpal tunnel syndrome patients. Journal of the Peripheral Nervous System. 2011 Mar;16(1):51-8.
Silva PG, Jones A, Fernandes AD, Natour J. Moberg Picking-Up Test in patients with hand osteoarthritis. Journal of Hand Therapy. 2017 Oct 1;30(4):522-8.
Stamm TA, Ploner A, Machold KP, Smolen J. Moberg pickingāup test in patients with inflammatory joint diseases: A survey of suitability in comparison with button test and measures of disease activity. Arthritis Care & Research: Official Journal of the American College of Rheumatology. 2003 Oct 15;49(5):626-32.
Moberg Pickup Test. : https://www.youtube.com/watch?v=fxr5c_Uh5ss&t=68s
Amirjani N, Ashworth NL, Gordon T, Edwards DC, Chan KM. Normative values and the effects of age, gender, and handedness on the Moberg PickāUp Test. Muscle & Nerve: Official Journal of the American Association of Electrodiagnostic Medicine. 2007 Jun;35(6):788-92.
D'souza SA, Kishan V. Moberg Pick-Up Test (Indian version): Test-retest Reliablity and Normative Values for Indian Adults of 30 to 60 years. Indian Journal of Occupational Therapy. 2010 Sep 1;42(3).